remOVE SecureCap

Elastic and transparent retrieval cap To remOVE SecureCap
Category:

Description

+49 (0) 7071 96528 160
service@ovesco.com

Use of the remOVE SecureCap

The remOVE SecureCap allows safe extraction of the clip fragments and ingested foreign objects in the digestive tract.

The remOVE SecureCap

The remOVE SecureCap is an elastic and transparent retrieval cap. It is available in two versions

  • remOVE SecureCap 12 (for the upper gastrointestinal tract)
  • remOVE SecureCap 14 (for the lower gastrointestinal tract)

The remOVE SecureCap is part of the remOVE DC Cutter and of the remOVE FBR Set.

Dimensions and specifications

remOVE SecureCap 12remOVE SecureCap  14
Suitable for endoscope diameter [a]9.5 – 12 mm12 – 14 mm
Max. outer diameter [b]16.9 mm17.0 mm
Internal chamber of the cap [c]19.5 mm19.9 mm
Items per package11
Reference number of the remOVE DC Cutter SetremOVE DC Cutter Set 12: 400.02.01 (incl. remOVE DC Cutter, remOVE SecureCap 12, remOVE Grasper and remOVE Shield);

remOVE FBR Set:

400.05 (incl. remOVE SecureCap 12 und remOVE Grasper)

remOVE DC Cutter Set 14:

400.02.02 (incl. remOVE DC Cutter, remOVE SecureCap 14, remOVE Grasper and remOVE Shield)

 

Application of the remOVE SecureCap

Step 1: The remOVE SecureCap is mounted onto the endoscope tip

Step 2: The endoscope, with the fitted remOVE SecureCap, is guided by sight to the foreign body or clip fragment.

 

3_Clipfragment-in-SecureCap

Step 3: The foreign body or the clip fragment is carefully drawn into the remOVE SecureCap and retrieved from the body. This method ensures that the remOVE Grasper securely holds the foreign body or the clip fragment in the remOVE SecureCap as the endoscope is retracted.

 

 

3_Clipfragment-in-SecureCap

Example:

Situation after endoscopic full-thickness resection with the FTRD® System in sigma. Clip removal for monitoring. *

FTRD® clip in the sigmoid colon

remOVE DC Cutter is positioned at the clip bow

The clip bow is effectively cut

The clip is cut at a point opposite of the first cut

Extraction of a clip fragment by using the remOVE Grasper and the remOVE SecureCap

extracted clip fragments

*Source: Prof. Dr. K. Caca und Dr. A. Schmidt, Klinikum Ludwigsburg, Dept. of Internal Medicine, Gastroenterology, Hemato-Oncology, Diabetes and Infectious Diseases, Germany

Media

FILTER:

remOVE System Video
Condition after endoscopic full tissue resection with the FTRD® system in the sigma. Clip removal
Clip removal with AWC®
Shows facilitated clip removal with AWC®. Clip can be fixed during procedure to allow better
BougieCap procedure
Shows the bougienage of a Malignant Esophageal Obstruction with BougieCap and guidwire
BougieCap procedure
Shows the bougienage of a refractory esophageal anastomic stricture
BougieCap procedure
Shows the bougienage of a esophageal introital stenosis
Clip removal with AWC®
Shows facilitated clip removal with AWC®. Clip can be fixed during procedure to allow better
BougieCap procedure
Shows the bougienage of a peptic esohageal stenosis with two BougieCap sizes
BougieCap procedure
Shows the bougienage of a pyloric stenosis
BougieCap procedure
Shows the bougienage of a long esophageal stricture
remOVE with AWC
Infoflyer
remOVE System Brochure
Brochure
remOVE BougieCap
Infoflyer
remOVE FBR Set
Infoflyer
remOVE DC IMPULSE
Instructions for use
remOVE BougieCap
A new method for treatment of esophageal strictures
remOVE with AWC
Infoflyer

Other products of the remOVE System product family

TOP